MIL-DTL-5003E
AMERICAN SOCIETY FOR QUALITY (ASQ)
ASQ Z1.4
- Sampling Procedures and Tables for Inspection by
Attributes
(Copies of this document are available online at https://www.asq.org/ or from American Society
of Quality, 600 North Plankinton Avenue, Milwaukee, WI 53203.)
SAE INTERNATIONAL
SAE AMS-QQ-P-416
- Plating, Cadmium (Electrodeposited)
(Copies of this document are available from https://www.sae.org/ or from SAE International, 400
Commonwealth Drive, Warrendale, PA 15096-0001.)
SSPC: THE SOCIETY FOR PROTECTIVE COATINGS
SSPC-Paint 25
- Zinc Oxide, Alkyd, Linseed Oil Primer for Use
Over Hand Cleaned Steel Type I and Type II
(Copies of this document are available from https://www.sspc.org/ or from SSPC: The Society
for Protective Coatings, 40 24th Street, 6th Floor, Pittsburgh, PA 15222-4656.)
2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event
of a conflict between the text of this document and the references cited herein, the text of this
document takes precedence. Nothing in this document, however, supersedes applicable laws and
regulations unless a specific exemption has been obtained.
3. REQUIREMENTS
3.1 First article. Unless otherwise specified (see 6.2), a sample shall be subjected to first
article inspection in accordance with 4.2.
3.2 Description. The tripod-mounted, electric floodlight set (herein after referred to as
"lamp assembly") shall be as shown in figures 1 through 5 and as specified herein.
3.2.1 Figures. No deviations from the prescribed dimensions or tolerances are
permissible without prior approval of the contracting officer. Where tolerances could
cumulatively result in incorrect fits, the contractor shall provide tolerances within those
prescribed on the figures to insure correct fit, assembly, and operation of the lamp assembly.
Any data (e.g., shop drawings, layouts, flow sheets, processing procedures, etc.) prepared by the
contractor or obtained from a vendor to support fabrication and manufacture of the production
items shall be made available, upon request, for inspection by the contracting officer or the
designated representative.