A-A-50815A
DEFECTS (continued).
Light base does not have slotted hole for wall mounting.
Exposed metal surface is not free from bends, dents, or cracks.
Exposed light surface is not free from burrs or sharpness.
Internal wiring is bare of insulation.
Wire raceway is not free from burrs or sharp edges.
Adequate strain relief is not provided throughout light.
Light finish is not as specified.
Light surface is scratched or marred.
Light cord is less than 5 feet in length.
Two spare lamps are not furnished.
Sampling for tests. Sampling for tests (including dimensional tests), shall be conducted in accordance with MIL-STD-105, with an AQL of 0 (percent defective) and an inspection level of S-2. The unit of product for test purposes shall be one desk light.
a. First article. Where a first article sample is required, all tests shall be performed on that unit.
b. Acceptance testing. When a first article sample has not been required, one unit shall be subjected to the performance test specified herein. If a test article sample has successfully passed all tests, performance test shall not be required at acceptance.
Tests
Dielectric withstand. The light shall be tested for dielectric withstand as specified in UL 153 (Portable Electric Lamps). Any signs of dielectric breakdown shall constitute a defect.
Leakage current. The light shall be tested for leakage current as specified in UL 1262 (Laboratory Equipment). Leakage current greater than 0.5 milliamperes shall constitute a defect.